| You are at: PSU > LEPA > LEPA Gold > 1200W | |
| Model G1200-MA | |

![]() |
Surpassing 80 Plus Gold level |
![]() |
Hybrid Modular Cabling Design makes system upgrade and replacement easy |
![]() |
135mm ball bearing fan with thermal programmed speed controller delivers silent, cool operation |
![]() |
Honeycomb-shaped ventilation design increases airow and keeps power supply cool |
![]() |
Solid State Capacitors and 100% 105oC Japanese Grade A Electrolytic Capacitors provide |
![]() |
DC-to-DC Converter Design ensures system stability |
![]() |
LLC Resonant Converter Topology achieves high eciency |
![]() |
Zero Voltage Switch (ZVS) topology provides superior performance and reliability |
![]() |
Dual Sided PCB design synergizes PCB layout |
![]() |
Four powerful +12V rails with high maximum loads offer great compatibility with |
![]() |
Compliance with EU ErP Lot 6 2013 standards |
![]() |
Over Power, Over Current, Over Voltage, Under Voltage, Over Temperature, |
![]() |
ATX12V version 2.3 and EPS12V version 2.92 compliant |
| Model Number: G1200-MA | |||||||||
| AC Input Voltage | 115 - 240VAC, 50 - 60Hz (Maximum range: 100-240 VAC, 50-60Hz) |
||||||||
| AC Input Current | 14 - 6A | ||||||||
| DC Output | +3.3V | 0-24A | |||||||
| +5V | 0-24A | ||||||||
| +3.3V & +5V | 120W | ||||||||
| 12V1 | 0-30A | ||||||||
| 12V2 | 0-30A | ||||||||
| 12V3 | 0-30A | ||||||||
| 12V4 | 0-30A | ||||||||
| -12V | 0-0.5A | ||||||||
| +5Vsb | 3A | ||||||||
+12V |
1200W (100A) | ||||||||
| Total Power | 1200W | ||||||||
| Peak Power | 1320W | ||||||||
| MTBF | > 100,000 hours @25oC | ||||||||
| Operating Temp. | 0oC ~ 50oC | ||||||||
| Dimension | 175mm (D) x 150mm (W) x 86mm (H) | ||||||||
| Net Weight | 2.5kg (without modular cables) +/-50g | ||||||||
| Protection Trigger Range | |||
| +3.3V | +5V | +12V1 / V2 / V3 / V4 | |
| Over Current Protection | 30A ~ 40A | 30A ~ 40A | 45A ~ 55A |
| Under Voltage Protection | 2.0V ~ 2.4V | 3.3V ~ 3.7V | 8.5V ~ 9.5V |
| Over Voltage Protection | 3.7V ~ 4.1V | 5.7V ~ 6.5V | 13.1V ~ 14.5V |
| Protection Point | |||
| Over Power Protection | Triggered when output power > 120 ~ 150% of rated max load | ||
| Over Temperature Protection | Triggered when PSU heat sink > 90oC ~ 120oC | ||
| Short Circuit Protection | Main output power shall latch into shut down state within 50ms when short circuit applied. +5Vsb is designed as auto recovery mode protection. |



![]() |